This listing is closed

Myers Lab 3 Centrifugal Molecular Distillation System (Buyer to Arrange Uplift ,Collection ,and Removal of this Asset from West Beach Site Sa )

$2,000.00 start

2 Hamra Avenue, West Beach SA, Australia
Bidding is closed for this item.

Lot Information

Lot Description

Centrifugal Molecular Distillation (Process Up To 0.9 Kg/Hour) Is A Purification Technique Which Has Gained Wide Acceptance In The Chemical, Food Processing, Pharmaceutical And Petroleum Industries As Well As The Specialty Chemicals Industry.

The Principle Behind The Myers Vacuum Centrifugal Molecular Stills Is Low Pressure And Extremely Short Residence Time. Once The Feed Material Has Been Degassed, It Flows Onto The Spinning Heated Disc. Distillation Takes Place In Less Than 1 Second As The Material Expands Out Exponentially On The Radius Of The Disc. The Residue Is Caught Within A Gutter Surrounding The Rotor And Then Flows Down To The Collecting Vessel Below. The Distillate Condenses On The Outer Shell Of The Still And Flows By Gravity To Another Collecting Vessel Also Below The Still.

Includes:

Consisting Of 3 Modules:

 

Still Assembly, (287705)

• Degassing Feed Chamber (420 M Litre Max. Volume)

• 3" Diameter Heated Rotor

• Water-Cooled Condenser Surface

• Feed Valve

• Distillate/Residue Valves

• Distillate/Residue Collecting Vessels (465 M Litre Max. Volume Each)

• Recycle Line From Residue Vessel Returning To The Degassing Chamber For Multiple Pass Operation

• Components Are Mounted On A Stand

• Wetted Components Are Stainless Steel, Viton Seals With A Minimum Of Glassware. Pumping System (285275)

• 2" Diffusion High Vacuum Pump

• Mechanical Pump

• Vacuum Cold Trap

• Stainless Steel Vacuum Manifold And Valves

• Water Manifold With Valves

 

Two (2) Digital Thermistor Vacuum Gauges:

Myers GT-430 With Trend Sensing TM And High Sensitivity To Monitor Vacuum Pressures And Leak Detection Of The Main Chamber And Fore Line.

• Digital Temperature Controller,

• Individual Switches For Rotation, Heater Mechanical And Diffusion Pump Operation

• Switched/Variable Power Outlet For The Addition Of Heat Tapes.

 

Transformer And Some Spare Parts

 

Bid History

This Lot currently has no bids.

Auction Description

Laboratory BioTech and Scientific Equipment

Location: Located at West Beach, SA

 Inspection: By Appointment!

Collection:  By Appointment!


* Paid In Full Invoice Required To Collect Goods

* No Payment Facilities Available Onsite

* NO Lifting Facilities Available - Bring Appropriate Tools & Help with You
* Any Goods Not Collected In These Times Will Be Forfeited

Important Information

Item Code 104800+4
Safety Advice WHS hazard assessment may be required before being placed into use.
Views This item has been viewed 756 times.